Novia 1000 Vapour Control Layer 100m2 Roll

Trade prices for all

Fast online ordering

Click & Collect

Nationwide Delivery

Trade prices for all

Fast online ordering

Original price was: £170.48.Current price is: £161.96. Inc VAT

Free Delivery on Novia orders over £1200 (incl VAT)

Delivery: 2 - 4 Days
Sale!

Order Online

Best Prices

Novia 1000 Vapour Control Layer 100m2 Roll

Original price was: £170.48.Current price is: £161.96. Inc VAT

Free Delivery on Novia orders over £1200 (incl VAT)

Delivery: 2 - 4 Days

Everyday Low Prices

Our huge buying power with leading manufacturers means lower prices for you

Novia 1000 Vapour Control Layer – 4m x 25m – 100m²

Novia 1000 is a medium-specification, virgin-grade blown polythene Air and Vapour Control Layer (AVCL) designed to control the passage of water vapour and unwanted air leakage through insulated building constructions. It is particularly suitable for timber frame walls and other applications where a reliable, cost-effective vapour control membrane is required.

Positioned between Novia’s lighter and heavier blown-polythene VCL options, Novia 1000 provides a traditional single-ply, non-laminated vapour control solution for insulated wall, roof and floor applications.

In addition to vapour control, the membrane also performs as an air leakage barrier, helping reduce heat losses caused by unwanted convection flows through the building envelope.

Novia 1000 is CE approved, CPR compliant and UKCA approved to EN 13984. It should be professionally installed using the Novia 2-tape sealing system to create a continuous airtight and vapour-resistant layer.

Supplied multi-folded at 4m x 25m, each membrane provides 100m² nominal coverage.

Why Choose Novia 1000 Vapour Control Layer?

Key benefits include:

  • 4m x 25m membrane
  • 100m² nominal coverage
  • Medium-specification AVCL
  • Virgin-grade blown polythene
  • Single-ply, non-laminated construction
  • Vapour control layer
  • Air leakage barrier
  • Suitable for timber frame walls
  • Suitable for insulated wall applications
  • Suitable for insulated roof applications
  • Suitable for insulated floor applications
  • Controls the passage of moisture vapour
  • Helps minimise the risk of interstitial condensation
  • Helps restrict unwanted convection flows
  • Can help improve insulation performance
  • Translucent green tint
  • Battens and framing remain visible during installation
  • CE approved
  • CPR compliant
  • UKCA approved to EN 13984
  • Cost-effective vapour control solution
  • Install with Novia 2-tape sealing system
  • Compatible with Novia Double Sided Butyl Tape
  • Compatible with Novia Metallised BOPP Tape
  • Novia AirSeal 310 available for difficult sealing details
  • Ideal for use with appropriate Novia breather membranes

What Is Novia 1000 VCL Used For?

Novia 1000 is designed for applications where control of moisture vapour and unwanted air movement through insulated construction is required.

Typical applications include:

  • Timber frame walls
  • Insulated wall construction
  • Insulated roof construction
  • Insulated floor construction
  • Timber-framed dwellings
  • Insulated frame applications
  • Vapour control
  • Air leakage control
  • Condensation management strategies
  • Airtight building envelope construction

The membrane should be positioned and installed according to the requirements of the complete wall, roof or floor build-up.

What Is a Vapour Control Layer?

A Vapour Control Layer, commonly abbreviated to VCL, helps regulate the movement of water vapour through insulated building elements.

Moisture vapour is naturally produced within occupied buildings through everyday activities such as:

  • Cooking
  • Washing
  • Showering
  • Drying clothes
  • General occupancy

Without suitable vapour control, this moisture can migrate into colder parts of the building fabric where condensation may occur.

A correctly specified VCL helps control this movement.

Air and Vapour Control Layer

Novia 1000 also provides an air leakage control function, making it an Air and Vapour Control Layer or AVCL.

The membrane therefore provides two related functions:

Vapour Control

helping restrict the movement of moisture vapour through the building envelope.

Air Leakage Control

helping restrict uncontrolled air movement through gaps in the construction.

Air Leakage Barrier

Uncontrolled movement of heated air through the building fabric can contribute to unnecessary heat loss.

Novia 1000 performs as an air leakage barrier, helping prevent losses caused by unwanted convection flows when installed as a continuous and properly sealed membrane.

Correct detailing is particularly important around:

  • Membrane overlaps
  • Edges and perimeters
  • Corners
  • Roof-to-wall junctions
  • Wall-to-floor junctions
  • Windows and doors
  • Service penetrations
  • Structural penetrations

Helps Improve Insulation Performance

Air movement through and around insulation can reduce the effectiveness of the insulated building envelope.

By helping limit unwanted convection flows, Novia 1000 can help the insulation within the construction perform more effectively.

Overall thermal performance will still depend on factors including:

  • Insulation specification
  • Construction design
  • Airtightness detailing
  • Thermal bridging
  • Installation quality

Helps Minimise Interstitial Condensation

Novia 1000 helps control the movement of water vapour into insulated building elements.

This can help minimise the risk of interstitial condensation, where moisture forms within the layers of a wall, roof or floor.

The complete construction should still be assessed for condensation risk and designed according to its specific moisture management requirements.

Virgin-Grade Blown Polythene

Novia 1000 is manufactured from virgin-grade blown polythene.

Its construction is:

  • Single-ply
  • Non-laminated
  • Traditional blown polythene

This provides a straightforward, economical vapour control solution for appropriate insulated building applications.

Medium-Specification VCL

Novia 1000 is positioned as a medium-specification blown-polythene vapour control membrane.

It sits within Novia’s range of conventional polythene VCL products and offers a balance between material specification and cost.

Where a heavier or higher-specification vapour control solution is required, another product within the Novia VCL range may be more appropriate.

Suitable for Timber Frame Walls

Novia 1000 is particularly suitable for timber frame wall construction.

Within an appropriately designed timber frame wall, it can form the internal air and vapour control layer.

A suitable Novia breather membrane can then be incorporated within the appropriate external side of the construction.

Together, the membranes can form part of a system designed to provide:

  • Internal air control
  • Internal vapour resistance
  • External breathable membrane protection

Suitable for Insulated Roofs

Novia identifies the 1000 VCL for appropriate insulated roof applications.

Within a correctly designed roof build-up, the membrane can provide the required internal air and vapour control function.

The exact position and detailing should follow the requirements of the roof construction.

Suitable for Insulated Floors

Novia 1000 can also be used within appropriate insulated floor applications.

This allows the membrane to be used across multiple insulated building elements where the same level of air and vapour control is required.

Translucent Green Tint

Novia 1000 has a translucent green tint.

This allows battens, timber framing and other underlying construction elements to remain visible through the membrane during installation.

This can help with:

  • Positioning
  • Fixing
  • Locating battens
  • Identifying framing members

4m x 25m Multi-Folded Format

Novia 1000 is supplied:

4m wide x 25m long

providing:

100m² nominal coverage

The membrane is supplied multi-folded, making the large-format sheet more practical to handle before and during installation.

Actual usable coverage will be lower after allowing for overlaps, cutting and installation wastage.

Professional Installation

Novia states that 1000 VCL should be professionally installed using the specified sealing system.

An AVCL only performs effectively when continuity is maintained across the complete building element.

Poorly sealed:

  • Joints
  • Laps
  • Penetrations
  • Edges
  • Junctions

can allow both air and moisture vapour to bypass the membrane.

Novia 2-Tape Sealing System

Novia specifies a 2-tape sealing system for the 1000 VCL.

This comprises:

Novia Double Sided Butyl Tape

and:

Novia Metallised BOPP Tape

The combination helps maintain a complete air and vapour seal at membrane overlaps.

Novia Double Sided Butyl Tape

Novia Double Sided Butyl Tape is positioned between overlapping sheets of membrane.

It provides a high-performance seal to help prevent the passage of:

  • Air
  • Moisture vapour

through the membrane joint.

The tape should not be relied upon as a structural fixing, and mechanical fixing should be provided where required.

Novia Metallised BOPP Tape

Novia Metallised BOPP Tape is used across the face of the membrane joint as the final secure lap seal.

Together with the Double Sided Butyl Tape within the overlap, this forms the recommended Novia 2-tape sealing system.

Novia AirSeal 310

Some building details can be difficult to seal effectively using tapes alone.

For these areas, Novia AirSeal 310 is available for appropriate:

  • Complex junctions
  • Irregular edges
  • Penetrations
  • Corners
  • Difficult sealing details
  • Additional sealing support

This can help maintain continuity of the air and vapour control layer around challenging construction details.

Use with Novia Breather Membranes

Novia recommends using 1000 VCL in combination with an appropriate Novia breather membrane within insulated frame applications.

The two membranes perform different functions.

Novia 1000 VCL:

  • Restricts moisture vapour movement
  • Controls air leakage
  • Forms the appropriate internal membrane layer

Novia Breather Membrane:

  • Provides the specified external membrane function
  • Allows moisture vapour to pass through
  • Forms the appropriate external membrane layer

The correct combination should be selected according to the complete construction.

CE Approved, CPR Compliant and UKCA Approved

Novia 1000 is specified as:

  • CE approved
  • CPR compliant
  • UKCA approved to EN 13984

EN 13984 covers flexible sheets used as plastic and rubber vapour control layers within buildings.

Helps Towards BS 5250 Requirements

Novia states that the membrane can help buildings towards the requirements of BS 5250:2011.

Its air and vapour control functions can form part of a wider condensation and moisture management strategy.

The complete building element should still be assessed according to its individual construction and exposure conditions.

Cost-Effective AVCL

Novia 1000 provides a low-cost solution for appropriate air and vapour control applications.

Its traditional blown-polythene construction makes it suitable where a straightforward VCL is required without the reinforced or reflective characteristics of more specialist membranes.

Novia 1000 Vapour Control Layer Specification

Specification Details
Product Novia 1000
Product Type Air & Vapour Control Layer
Specification Medium
Material Virgin-Grade Blown Polythene
Construction Single-Ply, Non-Laminated
Sheet Width 4m
Sheet Length 25m
Nominal Coverage 100m²
Supply Format Multi-Folded
Vapour Control Yes
Air Leakage Barrier Yes
Timber Frame Walls Suitable
Insulated Walls Suitable
Insulated Roofs Suitable
Insulated Floors Suitable
Colour Translucent Green Tint
Standard EN 13984
UKCA Approved Yes
CE Approved Yes
CPR Compliant Yes
BS 5250:2011 Helps Towards Requirements
Installation Professional Installation Required
Jointing System Novia 2-Tape Sealing System
Primary Joint Tape Novia Double Sided Butyl Tape
Final Lap Seal Novia Metallised BOPP Tape
Additional Sealant Novia AirSeal 310
Compatible Breather Membranes Appropriate Novia Breather Membranes

Frequently Asked Questions

What is Novia 1000 Vapour Control Layer?

Novia 1000 is a medium-specification virgin-grade blown-polythene Air and Vapour Control Layer designed to control moisture vapour and unwanted air leakage through insulated building construction.

What size is Novia 1000?

Each membrane measures:

4m x 25m

How much does one Novia 1000 membrane cover?

Each membrane provides:

100m² nominal coverage

Actual usable coverage will be lower after allowing for overlaps, cutting and installation wastage.

Is Novia 1000 a VCL or AVCL?

It performs both vapour control and air leakage control, so it can be described as an Air and Vapour Control Layer or AVCL.

What is Novia 1000 made from?

It is made from virgin-grade blown polythene.

Is Novia 1000 reinforced?

No. The supplied specification describes Novia 1000 as a single-ply, non-laminated blown-polythene membrane.

For applications requiring a reinforced membrane, an appropriate reinforced Novia VCL should be selected.

Is Novia 1000 suitable for timber frame construction?

Yes. Timber frame walls are one of the key intended applications for Novia 1000.

Can Novia 1000 be used in walls?

Yes. It is suitable for appropriate insulated wall applications, including timber frame walls.

Can Novia 1000 be used in roofs?

Yes. Novia specifies the membrane for appropriate insulated roof applications.

Can Novia 1000 be used in floors?

Yes. It is also designed for appropriate insulated floor applications.

Does Novia 1000 help prevent condensation?

Novia 1000 controls the passage of moisture vapour and can therefore help minimise the risk of interstitial condensation as part of a correctly designed construction.

Does Novia 1000 reduce air leakage?

Yes. It performs as an air leakage barrier, helping prevent unwanted convection flows through the building envelope.

Can Novia 1000 improve insulation performance?

By restricting uncontrolled air movement, Novia 1000 can help the complete insulated construction perform more effectively.

The actual thermal performance depends on the complete building element.

What colour is Novia 1000?

It has a translucent green tint.

Can you see battens through Novia 1000?

Yes. Its translucent construction allows underlying battens and framing to remain visible during installation.

Which tapes should be used with Novia 1000?

Novia recommends its 2-tape sealing system, comprising:

  • Novia Double Sided Butyl Tape within the overlap
  • Novia Metallised BOPP Tape as the final secure lap seal

What can be used for difficult sealing areas?

Novia AirSeal 310 is available for complex areas that are difficult to seal with tapes or where additional sealing support is required.

Should Novia 1000 be used with a breather membrane?

Yes. Novia recommends combining the VCL with an appropriate Novia breather membrane within insulated frame applications.

Is Novia 1000 CE approved?

Yes. The supplied specification states that Novia 1000 is CE approved.

Is Novia 1000 CPR compliant?

Yes. It is stated as fully CPR compliant.

Is Novia 1000 UKCA approved?

Yes. Novia 1000 is UKCA approved to EN 13984.

What standard does Novia 1000 comply with?

The membrane is approved to EN 13984 for vapour control layer applications.

Is Novia 1000 a low-cost VCL?

Yes. Novia positions it as a cost-effective vapour control solution within its range.

What is the difference between Novia 1000 and Novia 1200?

Both are traditional blown-polythene Air and Vapour Control Layers.

Novia positions 1000 between its 500G and 1200G membranes in terms of thickness and specification, with 1200 providing the heavier option.

The exact physical properties should be checked against the relevant current Novia technical datasheets when required for specification.

Is Novia 1000 a breather membrane?

No. Novia 1000 is an air and vapour control membrane.

A breather membrane performs a different function and is normally positioned within the appropriate external part of an insulated construction.

How many sheets do I need?

Each membrane provides 100m² nominal coverage.

As a simple guide:

  • 100m² = approximately 1 sheet
  • 200m² = approximately 2 sheets
  • 300m² = approximately 3 sheets
  • 400m² = approximately 4 sheets
  • 500m² = approximately 5 sheets

Additional material should be allowed for membrane overlaps, cutting and installation wastage.

Novia 1000 Vapour Control Layer

Novia 1000 is a medium-specification, virgin-grade blown-polythene AVCL designed for insulated walls, roofs and floors, with particular suitability for timber frame construction.

The membrane combines vapour control with air leakage control, helping restrict moisture movement, minimise the risk of interstitial condensation and reduce heat losses caused by unwanted convection flows.

Novia 1000 is CE approved, CPR compliant and UKCA approved to EN 13984 and should be professionally installed using the Novia Double Sided Butyl Tape and Metallised BOPP Tape 2-tape sealing system.

Supplied multi-folded at 4m x 25m with 100m² nominal coverage, Novia 1000 provides a practical and cost-effective air and vapour control solution for a wide range of compatible insulated building applications.

Additional information

SKU N1000G-VCL Categories , , , Tag Brand:

Rated as Excellent on Trustpilot

Our customer service is rated as excellent on Trustpilot where we have over 1500 genuine customer reviews.

Customers also bought

Secure Online Ordering

As a family-run business, your trust really matters to us. That’s why all orders and payments are placed securely through our website, helping to keep your details safe and your order processed correctly.

We use your card issuer’s 3D Secure checks, and all payments are encrypted and handled securely by Stripe, a trusted payment provider. We never see or store your card details, so you can order with confidence knowing you’re in safe hands with Roofin Online.

Nationwide Delivery

We offer nationwide delivery on most products.

Delivery times are in working days (excluding weekends and bank holidays). Orders placed after 12 noon are processed from the next working day.

Some products and locations have delivery restrictions. Available options and costs are calculated automatically at checkout.

Click & Collect

We offer free Click & Collect on most products in our online shop.

Available collection locations are displayed automatically in your basket and at checkout, based on the products you’re ordering.

We’ll contact you when your order is ready for collection. Please wait for confirmation before travelling.

Rated as Excellent

Our customer service is rated as excellent on Trustpilot where we have over 1500 genuine customer reviews.